1174 lines
55 KiB
SQL
1174 lines
55 KiB
SQL
--
|
|
-- $Id$
|
|
--
|
|
-- Script containing customer specific sql statements for the FACILITOR database
|
|
|
|
DEFINE thisfile = 'SZDB.SQL'
|
|
DEFINE dbuser = 'SZDB'
|
|
|
|
SET ECHO ON
|
|
SET DEFINE ON
|
|
COLUMN fcltlogfile NEW_VALUE fcltlogfile NOPRINT;
|
|
COLUMN fcltcusttxt NEW_VALUE fcltcusttxt NOPRINT;
|
|
WHENEVER SQLERROR CONTINUE;
|
|
SELECT adm.getscriptspoolfile('&thisfile') AS fcltlogfile FROM DUAL;
|
|
SPOOL &fcltlogfile
|
|
WHENEVER SQLERROR EXIT;
|
|
SELECT adm.checkscriptcust('&dbuser') AS fcltcusttxt FROM DUAL;
|
|
WHENEVER SQLERROR CONTINUE;
|
|
---------------------------------------
|
|
PROMPT &fcltcusttxt
|
|
---------------------------------------
|
|
SET DEFINE OFF
|
|
|
|
------ payload begin ------
|
|
|
|
|
|
CREATE OR REPLACE PACKAGE SZDB
|
|
AS
|
|
PROCEDURE processemail (pfrom IN VARCHAR2,
|
|
pto IN VARCHAR2,
|
|
psubject IN VARCHAR2,
|
|
pbody IN VARCHAR2,
|
|
psessionid IN VARCHAR2,
|
|
pemailkey IN NUMBER);
|
|
|
|
PROCEDURE mld_after_insert (p_melding_key IN NUMBER);
|
|
|
|
FUNCTION imp_getfield_nr (p_parseline IN VARCHAR2,
|
|
p_fielddelimitor IN VARCHAR2,
|
|
p_nr IN NUMBER
|
|
) RETURN VARCHAR2;
|
|
|
|
END;
|
|
/
|
|
|
|
CREATE OR REPLACE PACKAGE BODY SZDB
|
|
AS
|
|
-- Status: proven concept
|
|
PROCEDURE processemail (pfrom IN VARCHAR2,
|
|
pto IN VARCHAR2,
|
|
psubject IN VARCHAR2,
|
|
pbody IN VARCHAR2,
|
|
psessionid IN VARCHAR2,
|
|
pemailkey IN NUMBER
|
|
)
|
|
AS
|
|
sender prs_perslid.prs_perslid_key%TYPE;
|
|
kostenplaats prs_afdeling.prs_kostenplaats_key%TYPE;
|
|
newkey mld_melding.mld_melding_key%TYPE;
|
|
defaultstdmelding fac_setting.fac_setting_default%TYPE;
|
|
kkey_att mld_kenmerk.mld_kenmerk_key%TYPE;
|
|
kkey_mail mld_kenmerk.mld_kenmerk_key%TYPE;
|
|
errormsg fac_result.fac_result_waarde%TYPE;
|
|
BEGIN
|
|
-- Valideer de sender in pfrom: kennen we deze?
|
|
SELECT prs_perslid_key, d.prs_kostenplaats_key
|
|
INTO sender, kostenplaats
|
|
FROM prs_perslid p, prs_afdeling d
|
|
WHERE p.prs_afdeling_key = d.prs_afdeling_key
|
|
AND UPPER (prs_perslid_email) = UPPER (pfrom);
|
|
|
|
CASE
|
|
WHEN UPPER (pto) LIKE 'MELDING@%'
|
|
THEN
|
|
defaultstdmelding := 1;
|
|
kkey_att := 1;
|
|
kkey_mail := 2;
|
|
|
|
-- suggested extensions:
|
|
-- check for MLDUSE-write autorisations
|
|
-- parse the subject to find an appropriate stdmelding, if uniquely possible
|
|
-- append (as a note?) to an existing melding if #key is found in the subject
|
|
BEGIN
|
|
INSERT INTO mld_melding (mld_melding_module,
|
|
mld_meldbron_key,
|
|
mld_melding_datum,
|
|
mld_melding_onderwerp,
|
|
mld_melding_omschrijving,
|
|
mld_melding_status,
|
|
mld_stdmelding_key,
|
|
prs_perslid_key,
|
|
prs_perslid_key_voor,
|
|
prs_kostenplaats_key,
|
|
mld_melding_spoed)
|
|
VALUES ('MLD',
|
|
4, -- email
|
|
SYSDATE,
|
|
SUBSTR (psubject, 1, 80),
|
|
SUBSTR (REPLACE (SUBSTR (pbody, 1, 4000),
|
|
CHR (13) || CHR (10) || CHR (13) || CHR (10),
|
|
CHR (13) || CHR (10)),
|
|
1,
|
|
4000), -- verwijder onnodige witregels
|
|
NULL,
|
|
defaultstdmelding,
|
|
sender,
|
|
sender,
|
|
kostenplaats,
|
|
3)
|
|
RETURNING mld_melding_key
|
|
INTO newkey;
|
|
|
|
|
|
INSERT INTO fac_result (fac_result_sessionid,
|
|
fac_result_naam,
|
|
fac_result_waarde)
|
|
VALUES (psessionid,
|
|
'kenmerkpath',
|
|
'MLD\M' || to_char( TRUNC(newkey/1000), 'FM0000') || '___\M' || newkey || '\' || kkey_att || '\');
|
|
|
|
INSERT INTO fac_result (fac_result_sessionid,
|
|
fac_result_naam,
|
|
fac_result_waarde)
|
|
VALUES (psessionid,
|
|
'kenmerkorgmailpath',
|
|
'MLD\M' || TO_CHAR (TRUNC (newkey / 1000), 'FM0000') || '___\M' || newkey || '\' || kkey_mail || '\');
|
|
|
|
mld.setmeldingstatus (newkey, 2, sender);
|
|
END;
|
|
ELSE
|
|
NULL;
|
|
END CASE;
|
|
|
|
IF errormsg IS NOT NULL
|
|
THEN
|
|
INSERT INTO fac_result (fac_result_sessionid,
|
|
fac_result_naam,
|
|
fac_result_waarde)
|
|
VALUES (psessionid, 'errormsg', errormsg);
|
|
END IF;
|
|
EXCEPTION
|
|
WHEN OTHERS
|
|
THEN
|
|
fac.writelog (
|
|
'PROCESSEMAIL',
|
|
'W',
|
|
'Mail kon niet verwerkt worden afzender: '
|
|
|| pfrom
|
|
|| '['
|
|
|| errormsg
|
|
|| ']',
|
|
'OTHERS (error '
|
|
|| SQLCODE
|
|
|| '/'
|
|
|| SUBSTR (SQLERRM, 1, 100)
|
|
|| ')');
|
|
INSERT INTO fac_result (fac_result_sessionid,
|
|
fac_result_naam,
|
|
fac_result_waarde)
|
|
VALUES (psessionid,
|
|
'errormsg',
|
|
'Database fout - Neem contact op met uw systeembeheerder');
|
|
END;
|
|
|
|
PROCEDURE mld_after_insert (p_melding_key IN NUMBER)
|
|
AS
|
|
c_kenmerk_key MLD_KENMERK.MLD_KENMERK_KEY%TYPE := 43; -- Datum kamer beschikbaar
|
|
v_kenmerk_oms MLD_KENMERK.MLD_KENMERK_OMSCHRIJVING%TYPE;
|
|
v_kenmerkm_waarde MLD_KENMERKMELDING.MLD_KENMERKMELDING_WAARDE%TYPE;
|
|
v_melding_oms MLD_MELDING.MLD_MELDING_OMSCHRIJVING%TYPE;
|
|
c_stdmelding_key MLD_STDMELDING.MLD_STDMELDING_KEY%TYPE := 111; -- Mutatie / Nieuwe client
|
|
v_stdmelding_key MLD_STDMELDING.MLD_STDMELDING_KEY%TYPE;
|
|
BEGIN
|
|
SELECT COALESCE (mld_kenmerk_omschrijving, mld_srtkenmerk_omschrijving)
|
|
INTO v_kenmerk_oms
|
|
FROM mld_kenmerk k, mld_srtkenmerk sk
|
|
WHERE k.mld_srtkenmerk_key = sk.mld_srtkenmerk_key
|
|
AND k.mld_kenmerk_key = c_kenmerk_key;
|
|
|
|
SELECT mld_melding_omschrijving, mld_stdmelding_key
|
|
INTO v_melding_oms, v_stdmelding_key
|
|
FROM mld_melding
|
|
WHERE mld_melding_key = p_melding_key;
|
|
|
|
IF v_stdmelding_key = c_stdmelding_key
|
|
THEN
|
|
v_kenmerkm_waarde := FLX.getflex ('MLD', c_kenmerk_key, p_melding_key);
|
|
|
|
IF v_kenmerkm_waarde IS NOT NULL
|
|
THEN
|
|
IF INSTR (v_melding_oms, v_kenmerk_oms) = 1
|
|
THEN
|
|
-- Het kenmerk staat al in de omschrijving. Dan overschrijven we die.
|
|
v_melding_oms :=
|
|
v_kenmerk_oms
|
|
|| ': '
|
|
|| v_kenmerkm_waarde
|
|
|| CHR (10)
|
|
|| SUBSTR (v_melding_oms,
|
|
LENGTH (v_kenmerk_oms) + 14,
|
|
3900);
|
|
ELSE
|
|
v_melding_oms :=
|
|
v_kenmerk_oms
|
|
|| ': '
|
|
|| v_kenmerkm_waarde
|
|
|| CHR (10)
|
|
|| SUBSTR (v_melding_oms, 1, 3900);
|
|
END IF;
|
|
|
|
UPDATE mld_melding
|
|
SET mld_melding_omschrijving = v_melding_oms
|
|
WHERE mld_melding_key = p_melding_key;
|
|
END IF;
|
|
END IF;
|
|
|
|
COMMIT;
|
|
END;
|
|
|
|
FUNCTION imp_getfield_nr (p_parseline IN VARCHAR2,
|
|
p_fielddelimitor IN VARCHAR2,
|
|
p_nr IN NUMBER
|
|
) RETURN VARCHAR2
|
|
AS
|
|
v_return_str VARCHAR2(1000);
|
|
BEGIN
|
|
fac.imp_getfield_nr (p_parseline, p_fielddelimitor, p_nr, v_return_str);
|
|
RETURN v_return_str;
|
|
END;
|
|
|
|
END;
|
|
/
|
|
|
|
CREATE OR REPLACE VIEW szdb_v_mutatie_status
|
|
AS
|
|
SELECT m.mld_melding_key,
|
|
mld_melding_datum,
|
|
LISTAGG (
|
|
km.mld_kenmerk_omschrijving
|
|
|| ': '
|
|
|| km.mld_kenmerkmelding_waarde,
|
|
CHR (10))
|
|
WITHIN GROUP (ORDER BY km.mld_kenmerk_volgnummer)
|
|
AS details,
|
|
l.alg_locatie_code,
|
|
l.alg_locatie_omschrijving,
|
|
aog.alg_gebouw_code,
|
|
aog.alg_gebouw_naam,
|
|
aog.alg_verdieping_code,
|
|
aog.alg_ruimte_nr,
|
|
aog.alg_ruimte_omschrijving,
|
|
FLX.getflex('MLD', 43, m.mld_melding_key) kamer_leeg,
|
|
ms.mld_statuses_omschrijving,
|
|
o.mld_opdr_bedrijfopdr_volgnr,
|
|
COALESCE (pf.prs_perslid_naam_full, b.prs_bedrijf_naam)
|
|
uitvoerder,
|
|
o.mld_opdr_plandatum,
|
|
os.mld_statusopdr_omschrijving,
|
|
o.mld_opdr_omschrijving
|
|
FROM mld_melding m,
|
|
mld_opdr o,
|
|
prs_v_perslid_fullnames_all pf,
|
|
prs_bedrijf b,
|
|
mld_statuses ms,
|
|
mld_statusopdr os,
|
|
alg_v_allonrgoed_gegevens aog,
|
|
alg_locatie l,
|
|
(SELECT km.mld_melding_key,
|
|
k.mld_kenmerk_volgnummer,
|
|
k.MLD_KENMERK_OMSCHRIJVING,
|
|
km.mld_kenmerkmelding_waarde
|
|
FROM mld_kenmerk k, mld_kenmerkmelding km
|
|
WHERE k.mld_kenmerk_key = km.mld_kenmerk_key
|
|
AND k.mld_kenmerk_omschrijving IS NOT NULL) km
|
|
WHERE mld_stdmelding_key = 111 -- mutatie
|
|
AND m.mld_melding_key = o.mld_melding_key(+)
|
|
AND m.mld_melding_key = km.mld_melding_key(+)
|
|
AND o.mld_uitvoerende_keys = b.prs_bedrijf_key(+)
|
|
AND o.mld_uitvoerende_keys = pf.prs_perslid_key(+)
|
|
AND m.mld_melding_status = ms.mld_statuses_key
|
|
AND o.mld_statusopdr_key = os.mld_statusopdr_key(+)
|
|
AND m.mld_alg_onroerendgoed_keys = aog.alg_onroerendgoed_keys
|
|
AND m.mld_alg_locatie_key = l.alg_locatie_key
|
|
GROUP BY m.mld_melding_key,
|
|
ms.mld_statuses_omschrijving,
|
|
o.mld_opdr_bedrijfopdr_volgnr,
|
|
os.mld_statusopdr_omschrijving,
|
|
pf.prs_perslid_naam_full,
|
|
b.prs_bedrijf_naam,
|
|
o.mld_opdr_plandatum,
|
|
o.mld_opdr_omschrijving,
|
|
mld_melding_datum,
|
|
l.alg_locatie_code,
|
|
l.alg_locatie_omschrijving,
|
|
aog.alg_gebouw_code,
|
|
aog.alg_gebouw_naam,
|
|
aog.alg_verdieping_code,
|
|
aog.alg_ruimte_nr,
|
|
aog.alg_ruimte_omschrijving,
|
|
ms.mld_statuses_omschrijving;
|
|
|
|
-- Notificatie view om personen die een object op hun naam gekregen hebben te notificeren.
|
|
CREATE OR REPLACE VIEW szdb_v_noti_ins_2_prs
|
|
AS
|
|
SELECT 'CUST01' code,
|
|
NULL sender,
|
|
d.ins_alg_ruimte_key receiver,
|
|
'Ontvangstbevestiging ' || sd.ins_srtdeel_omschrijving || ' ' || d.ins_deel_omschrijving text,
|
|
d.ins_deel_key key,
|
|
NULL xkey
|
|
FROM fac_tracking t, ins_deel d, ins_srtdeel sd
|
|
WHERE t.fac_tracking_refkey = d.ins_deel_key
|
|
AND d.ins_srtdeel_key = sd.ins_srtdeel_key
|
|
AND UPPER (fac_tracking_oms) LIKE '%PLAATS OF EIGENAAR%'
|
|
AND fac_srtnotificatie_key = 137
|
|
AND ins_alg_ruimte_type = 'P'
|
|
AND t.fac_tracking_datum BETWEEN (SELECT fac_notificatie_job_nextrun
|
|
- fac_notificatie_job_interval
|
|
/ 24
|
|
FROM fac_notificatie_job
|
|
WHERE fac_notificatie_job_view =
|
|
'SZDB_V_NOTI_INS_2_PRS')
|
|
AND (SELECT fac_notificatie_job_nextrun
|
|
FROM fac_notificatie_job
|
|
WHERE fac_notificatie_job_view =
|
|
'SZDB_V_NOTI_INS_2_PRS');
|
|
|
|
-- MJOB
|
|
CREATE OR REPLACE PROCEDURE szdb_import_mjobelementen (p_import_key IN NUMBER)
|
|
IS
|
|
c_delim VARCHAR2 (2) := fac.import_delimiter(p_import_key);
|
|
v_newline fac_imp_file.fac_imp_file_line%TYPE; -- Input line
|
|
v_errormsg VARCHAR2 (1000);
|
|
v_errorhint VARCHAR2 (1000);
|
|
oracle_err_num NUMBER;
|
|
oracle_err_mes VARCHAR2 (200);
|
|
header_is_valid NUMBER;
|
|
v_count_tot NUMBER (10);
|
|
v_count_import NUMBER (10);
|
|
v_ongeldig NUMBER (1);
|
|
v_aanduiding VARCHAR (400);
|
|
v_dummy VARCHAR (255);
|
|
v_ins_kenmerk_key1 VARCHAR2 (255);
|
|
v_ins_kenmerk_key2 VARCHAR2 (255);
|
|
v_ins_kenmerk_key3 VARCHAR2 (255);
|
|
v_ins_kenmerk_key4 VARCHAR2 (255);
|
|
v_ins_kenmerk_key5 VARCHAR2 (255);
|
|
v_ins_kenmerk_key6 VARCHAR2 (255);
|
|
v_ins_kenmerk_key7 VARCHAR2 (255);
|
|
v_ins_kenmerk_key8 VARCHAR2 (255);
|
|
v_ins_kenmerk_key9 VARCHAR2 (255);
|
|
v_ins_kenmerk_key10 VARCHAR2 (255);
|
|
v_ins_kenmerk_key11 VARCHAR2 (255);
|
|
v_ins_kenmerk_key12 VARCHAR2 (255);
|
|
v_ins_kenmerk_key13 VARCHAR2 (255);
|
|
v_ins_kenmerk_key14 VARCHAR2 (255);
|
|
v_ins_kenmerk_key15 VARCHAR2 (255);
|
|
v_ins_kenmerk_key16 VARCHAR2 (255);
|
|
v_ins_kenmerk_key17 VARCHAR2 (255);
|
|
v_ins_kenmerk_key18 VARCHAR2 (255);
|
|
v_ins_kenmerk_key19 VARCHAR2 (255);
|
|
v_ins_kenmerk_key20 VARCHAR2 (255);
|
|
-- De importvelden
|
|
v_ins_discipline_omschrijving VARCHAR2 (255); -- C60
|
|
v_ins_discipline_kostensoort VARCHAR2 (255); --C60
|
|
v_ins_srtgroep_omschrijving VARCHAR2 (255); -- C60
|
|
v_ins_srtdeel_code VARCHAR2 (255); -- C10
|
|
v_ins_srtdeel_omschrijving VARCHAR2 (255); -- C100
|
|
v_ins_deel_omschrijving VARCHAR2 (255); -- C60
|
|
v_ins_deel_opmerking VARCHAR2 (1000); -- C320
|
|
v_ins_deel_externnr VARCHAR2 (255); -- C60
|
|
v_alg_locatie_code VARCHAR2 (255); -- C10
|
|
v_alg_gebouw_code VARCHAR2 (255); -- C12
|
|
v_alg_verdieping_volgnr VARCHAR2 (255); -- N3
|
|
v_alg_ruimte_nr VARCHAR2 (255); -- C20
|
|
|
|
v_ins_kenmerkwaarde1 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde2 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde3 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde4 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde5 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde6 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde7 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde8 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde9 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde10 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde11 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde12 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde13 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde14 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde15 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde16 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde17 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde18 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde19 VARCHAR2 (4053);
|
|
v_ins_kenmerkwaarde20 VARCHAR2 (4053);
|
|
v_ins_deel_aanmaak VARCHAR2 (255); -- DATE
|
|
v_ins_deel_aanmaak_d DATE;
|
|
v_ins_deel_vervaldatum VARCHAR2 (255); -- DATE
|
|
v_ins_deel_vervaldatum_d DATE;
|
|
v_ins_deel_aantal VARCHAR2 (255); -- N8,2
|
|
v_ins_deel_aantal_n NUMBER(8, 2);
|
|
v_file_index NUMBER;
|
|
|
|
v_alg_gebouw_key NUMBER;
|
|
v_alg_verdieping_key NUMBER;
|
|
v_alg_ruimte_key NUMBER;
|
|
v_ins_deel_key NUMBER;
|
|
v_ins_srtdeel_key NUMBER;
|
|
v_ins_srtgroep_key NUMBER;
|
|
v_ins_discipline_key NUMBER;
|
|
v_ins_deel_volgnr NUMBER;
|
|
-- Overige velden:
|
|
CURSOR c1
|
|
IS
|
|
SELECT *
|
|
FROM fac_imp_file
|
|
WHERE fac_import_key = p_import_key
|
|
ORDER BY fac_imp_file_index;
|
|
|
|
CURSOR c IS
|
|
SELECT *
|
|
FROM fac_imp_ins
|
|
ORDER BY alg_gebouw_code, ins_deel_omschrijving;
|
|
|
|
-- Controleer tijdens import-fase alleen op het bestaan van een kenmerk met de meegegeven omschrijving of kenmerk key.
|
|
-- De omschrijving (header van kolom) kan de omschrijving zijn van het kenmerksoort of het kenmerk.
|
|
-- De omschrijving van het kenmerksoort kan namelijk overruled worden door de omschrijving van het kenmerk.
|
|
-- Daarnaast kan hetzelfde kenmerk vaker voorkomen voor verschillende groepen.
|
|
-- Of het kenmerksoort/kenmerk wel is gedefinieerd voor de betreffende
|
|
-- object-discipline/groep/soort, volgt pas tijdens de update-fase)!
|
|
--
|
|
-- p_kw is bijvoorbeeld 'Parkeercode', 'Parkeercode|3', 234 of 234|3 waarbij de tweede en laatste in groep 3 zitten
|
|
-- het resultaat is NULL (als niet gevonden) of Parkeercode|3 of 234|3 voor kenmer_key 234 in groep 3
|
|
-- Als geen groep is meegegeven dan wordt 'Parkeercode|0' opgeleverd (de default groep)
|
|
FUNCTION bepaal_kenmerk (p_kw IN VARCHAR)
|
|
RETURN VARCHAR
|
|
IS
|
|
v_kenmerk_key NUMBER;
|
|
v_kenmerk_groep NUMBER;
|
|
v_kw VARCHAR(250);
|
|
BEGIN
|
|
v_kenmerk_groep := 0;
|
|
v_kw := p_kw;
|
|
IF INSTR (v_kw, '|') > 1
|
|
THEN
|
|
v_kenmerk_groep := SUBSTR (v_kw, INSTR (v_kw, '|') + 1);
|
|
v_kw := SUBSTR (v_kw, 1, INSTR (v_kw, '|') - 1);
|
|
END IF;
|
|
|
|
IF fac.safe_to_number (v_kw) IS NULL
|
|
THEN -- kenmerkwaarde is alfanumeriek (dus omschrijving)!
|
|
SELECT MIN(k.ins_kenmerk_key)
|
|
INTO v_kenmerk_key
|
|
FROM ins_v_aanwezigkenmerk k,
|
|
ins_v_aanwezigsrtkenmerk sk
|
|
WHERE k.ins_srtkenmerk_key = sk.ins_srtkenmerk_key
|
|
AND k.ins_kenmerk_groep = v_kenmerk_groep
|
|
AND COALESCE(UPPER(k.ins_kenmerk_omschrijving), sk.ins_srtkenmerk_upper) = UPPER(v_kw)
|
|
AND sk.ins_srtkenmerk_kenmerktype IN ('C', 'D', 'N', 'R', 'S', 'X', 'B', 'V');
|
|
ELSE -- kenmerkwaarde is numeriek (dus key)!
|
|
SELECT k.ins_kenmerk_key
|
|
INTO v_kenmerk_key
|
|
FROM ins_v_aanwezigkenmerk k,
|
|
ins_v_aanwezigsrtkenmerk sk
|
|
WHERE k.ins_srtkenmerk_key = sk.ins_srtkenmerk_key
|
|
AND k.ins_kenmerk_groep = v_kenmerk_groep
|
|
AND k.ins_kenmerk_key = fac.safe_to_number (v_kw)
|
|
AND sk.ins_srtkenmerk_kenmerktype IN ('C', 'D', 'N', 'R', 'S', 'X', 'B', 'V');
|
|
END IF;
|
|
|
|
IF v_kenmerk_key IS NULL
|
|
THEN
|
|
RETURN NULL;
|
|
ELSE
|
|
-- Er is een kenmerksoort of kenmerk aanwezig met de omschrijving/kenmerk_key (v_kw)
|
|
RETURN v_kw || '|' || TO_CHAR(v_kenmerk_groep);
|
|
END IF;
|
|
EXCEPTION
|
|
WHEN NO_DATA_FOUND
|
|
THEN
|
|
IF p_kw IS NULL OR UPPER (p_kw) LIKE 'KENMERK%'
|
|
THEN
|
|
RETURN NULL;
|
|
ELSE
|
|
fac.imp_writelog (p_import_key,
|
|
'W',
|
|
'Fout bij bepalen kenmerk [' || p_kw || ']',
|
|
'Bestaat niet of type ongeldig');
|
|
COMMIT;
|
|
RETURN NULL;
|
|
END IF;
|
|
END;
|
|
|
|
BEGIN
|
|
-- Eerst opruiming
|
|
DELETE FROM fac_imp_ins;
|
|
|
|
COMMIT;
|
|
|
|
v_count_tot := 0;
|
|
v_count_import := 0;
|
|
header_is_valid := 0;
|
|
|
|
FOR rec1 IN c1
|
|
LOOP
|
|
BEGIN
|
|
v_newline := rec1.fac_imp_file_line;
|
|
v_file_index := rec1.fac_imp_file_index;
|
|
v_errormsg := 'Fout bij opvragen importregel';
|
|
v_aanduiding := '';
|
|
v_ongeldig := 0;
|
|
-- Lees alle veldwaarden
|
|
fac.imp_getfield (v_newline, c_delim, v_alg_gebouw_code); -- Objectcode
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_srtdeel_code); -- Componentcode
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_deel_externnr); -- Element-ID
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_deel_opmerking); -- Component omschrijving
|
|
-- fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde1); -- Opmerkingen//
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde2); -- Fabrikant
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde3); -- Kenmerken
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde4); -- Type
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde5); -- Cap
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde6); -- Eenheid Cap
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_deel_aantal); -- Aantal
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde7); -- Eenheid aantal
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde8); -- Bouwjaar
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde9);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde10);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde11);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde12);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde13);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde14);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde15);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde16);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde17);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde18);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde19);
|
|
fac.imp_getfield (v_newline, c_delim, v_ins_kenmerkwaarde20);
|
|
|
|
v_aanduiding :=
|
|
'['
|
|
|| v_alg_gebouw_code
|
|
|| '|'
|
|
|| v_ins_deel_externnr
|
|
|| '|'
|
|
|| v_ins_srtdeel_code
|
|
|| '] ';
|
|
|
|
-- Ik controleer of ik een geldige header heb, dat is: in de juiste kolommen
|
|
-- de juiste kolomkop. Ik controleer daarbij alle NIET-kenmerk kolommen!
|
|
-- Ik negeer alles totdat ik een geldige header ben gepasseerd.
|
|
IF (header_is_valid = 0)
|
|
THEN
|
|
IF UPPER (v_alg_gebouw_code) = 'GEBOUW_CODE'
|
|
AND UPPER (v_ins_srtdeel_code) = 'SRTDEEL_CODE'
|
|
AND UPPER (v_ins_deel_externnr) = 'DEEL_EXTERNNR'
|
|
AND UPPER (v_ins_deel_opmerking) = 'DEEL_OPMERKING'
|
|
AND UPPER (v_ins_kenmerkwaarde2) = 'FABRIKANT'
|
|
AND UPPER (v_ins_kenmerkwaarde3) = 'OPMERKINGEN'
|
|
AND UPPER (v_ins_kenmerkwaarde4) = 'TYPE'
|
|
AND UPPER (v_ins_kenmerkwaarde5) = 'CAP'
|
|
AND UPPER (v_ins_kenmerkwaarde6) = 'EENHEID CAP'
|
|
AND UPPER (v_ins_deel_aantal) = 'DEEL_AANTAL'
|
|
AND UPPER (v_ins_kenmerkwaarde7) = 'EENHEID AANTAL'
|
|
AND UPPER (v_ins_kenmerkwaarde8) = 'BOUWJAAR'
|
|
THEN
|
|
v_ins_kenmerk_key1 := bepaal_kenmerk (v_ins_kenmerkwaarde1);
|
|
v_ins_kenmerk_key2 := bepaal_kenmerk (v_ins_kenmerkwaarde2);
|
|
v_ins_kenmerk_key3 := bepaal_kenmerk (v_ins_kenmerkwaarde3);
|
|
v_ins_kenmerk_key4 := bepaal_kenmerk (v_ins_kenmerkwaarde4);
|
|
v_ins_kenmerk_key5 := bepaal_kenmerk (v_ins_kenmerkwaarde5);
|
|
v_ins_kenmerk_key6 := bepaal_kenmerk (v_ins_kenmerkwaarde6);
|
|
v_ins_kenmerk_key7 := bepaal_kenmerk (v_ins_kenmerkwaarde7);
|
|
v_ins_kenmerk_key8 := bepaal_kenmerk (v_ins_kenmerkwaarde8);
|
|
v_ins_kenmerk_key9 := bepaal_kenmerk (v_ins_kenmerkwaarde9);
|
|
v_ins_kenmerk_key10 := bepaal_kenmerk (v_ins_kenmerkwaarde10);
|
|
v_ins_kenmerk_key11 := bepaal_kenmerk (v_ins_kenmerkwaarde11);
|
|
v_ins_kenmerk_key12 := bepaal_kenmerk (v_ins_kenmerkwaarde12);
|
|
v_ins_kenmerk_key13 := bepaal_kenmerk (v_ins_kenmerkwaarde13);
|
|
v_ins_kenmerk_key14 := bepaal_kenmerk (v_ins_kenmerkwaarde14);
|
|
v_ins_kenmerk_key15 := bepaal_kenmerk (v_ins_kenmerkwaarde15);
|
|
v_ins_kenmerk_key16 := bepaal_kenmerk (v_ins_kenmerkwaarde16);
|
|
v_ins_kenmerk_key17 := bepaal_kenmerk (v_ins_kenmerkwaarde17);
|
|
v_ins_kenmerk_key18 := bepaal_kenmerk (v_ins_kenmerkwaarde18);
|
|
v_ins_kenmerk_key19 := bepaal_kenmerk (v_ins_kenmerkwaarde19);
|
|
v_ins_kenmerk_key20 := bepaal_kenmerk (v_ins_kenmerkwaarde20);
|
|
|
|
header_is_valid := 1;
|
|
ELSE
|
|
IF rec1.fac_imp_file_index = 1
|
|
THEN
|
|
|
|
fac.imp_writelog (p_import_key,
|
|
'E',
|
|
'Ongeldige header aangetroffen:',
|
|
'GEBOUW_CODE: ' || UPPER (v_alg_gebouw_code) || CHR(10) ||
|
|
'SRTDEEL_CODE: ' || UPPER (v_ins_srtdeel_code) || CHR(10) ||
|
|
'DEEL_EXTERNNR: ' || UPPER (v_ins_deel_externnr) || CHR(10) ||
|
|
'DEEL_OPMERKING: ' || UPPER (v_ins_deel_opmerking) || CHR(10) ||
|
|
'FABRIKANT: ' || UPPER (v_ins_kenmerkwaarde2) || CHR(10) ||
|
|
'OPMERKINGEN: ' || UPPER (v_ins_kenmerkwaarde3) || CHR(10) ||
|
|
'TYPE: ' || UPPER (v_ins_kenmerkwaarde4) || CHR(10) ||
|
|
'CAP: ' || UPPER (v_ins_kenmerkwaarde5) || CHR(10) ||
|
|
'EENHEID CAP: ' || UPPER (v_ins_kenmerkwaarde6) || CHR(10) ||
|
|
'DEEL_AANTAL: ' || UPPER (v_ins_deel_aantal) || CHR(10) ||
|
|
'EENHEID AANTAL: ' || UPPER (v_ins_kenmerkwaarde7) || CHR(10) ||
|
|
'BOUWJAAR: ' || UPPER (v_ins_kenmerkwaarde8));
|
|
END IF;
|
|
END IF;
|
|
ELSE
|
|
v_count_tot := v_count_tot + 1;
|
|
-- Controleer alle veldwaarden
|
|
|
|
v_errormsg := 'Gebouwcode kan niet gevonden worden';
|
|
v_alg_gebouw_code := TRIM (v_alg_gebouw_code);
|
|
|
|
SELECT alg_gebouw_key, alg_locatie_code
|
|
INTO v_alg_gebouw_key, v_alg_locatie_code
|
|
FROM alg_gebouw g, alg_locatie l
|
|
WHERE g.alg_locatie_key = l.alg_locatie_key
|
|
AND alg_gebouw_verwijder IS NULL
|
|
AND UPPER(alg_gebouw_code) = v_alg_gebouw_code;
|
|
|
|
v_alg_verdieping_volgnr := 0;
|
|
BEGIN
|
|
SELECT alg_verdieping_key
|
|
INTO v_alg_verdieping_key
|
|
FROM alg_verdieping
|
|
WHERE alg_verdieping_verwijder IS NULL
|
|
AND alg_gebouw_key = v_alg_gebouw_key
|
|
AND alg_verdieping_volgnr = 0;
|
|
EXCEPTION WHEN NO_DATA_FOUND
|
|
THEN
|
|
INSERT INTO alg_verdieping (alg_gebouw_key, alg_verdieping_volgnr, alg_verdieping_omschrijving, alg_verdieping_code)
|
|
VALUES (v_alg_gebouw_key, 0, 'Begane grond', '0')
|
|
RETURNING alg_verdieping_key INTO v_alg_verdieping_key;
|
|
fac.imp_writelog (p_import_key, 'I', v_aanduiding, 'Verdieping aangemaakt');
|
|
END;
|
|
|
|
v_alg_ruimte_nr := '_';
|
|
BEGIN
|
|
SELECT alg_ruimte_key
|
|
INTO v_alg_ruimte_key
|
|
FROM alg_ruimte
|
|
WHERE alg_ruimte_verwijder IS NULL
|
|
AND alg_verdieping_key = v_alg_verdieping_key
|
|
AND alg_ruimte_nr = '_';
|
|
EXCEPTION WHEN NO_DATA_FOUND
|
|
THEN
|
|
INSERT INTO alg_ruimte (alg_verdieping_key, alg_ruimte_nr, alg_ruimte_omschrijving)
|
|
VALUES (v_alg_verdieping_key, '_', 'MJOP ruimte')
|
|
RETURNING alg_ruimte_key INTO v_alg_ruimte_key;
|
|
fac.imp_writelog (p_import_key, 'I', v_aanduiding, 'Ruimte aangemaakt');
|
|
END;
|
|
--
|
|
|
|
v_errormsg := 'Bepaal objectsoort';
|
|
BEGIN
|
|
v_ins_srtdeel_code := TRIM(v_ins_srtdeel_code);
|
|
SELECT ins_srtdeel_omschrijving, ins_srtdeel_key, ins_srtgroep_key
|
|
INTO v_ins_srtdeel_omschrijving, v_ins_srtdeel_key, v_ins_srtgroep_key
|
|
FROM ins_srtdeel
|
|
WHERE ins_srtdeel_verwijder IS NULL
|
|
AND ins_srtdeel_code = v_ins_srtdeel_code;
|
|
|
|
v_errormsg := 'Bepaal objectgroep';
|
|
SELECT ins_srtgroep_omschrijving, ins_discipline_key
|
|
INTO v_ins_srtgroep_omschrijving, v_ins_discipline_key
|
|
FROM ins_srtgroep
|
|
WHERE ins_srtgroep_key = v_ins_srtgroep_key;
|
|
|
|
v_errormsg := 'Bepaal discipline';
|
|
SELECT ins_discipline_omschrijving
|
|
INTO v_ins_discipline_omschrijving
|
|
FROM ins_discipline
|
|
WHERE ins_discipline_key = v_ins_discipline_key;
|
|
|
|
EXCEPTION WHEN NO_DATA_FOUND
|
|
THEN
|
|
v_errormsg := 'Nieuwe NL/SfB code';
|
|
v_ins_discipline_omschrijving := 'MJOB';
|
|
v_ins_srtdeel_omschrijving := v_ins_srtdeel_code || 'Onbekend';
|
|
BEGIN
|
|
SELECT ins_srtgroep_omschrijving
|
|
INTO v_ins_srtgroep_omschrijving
|
|
FROM ins_v_srtgroep_gegevens
|
|
WHERE ins_discipline_omschrijving = 'MJOB'
|
|
AND SUBSTR(v_ins_srtdeel_code, 1, 2) = SUBSTR(ins_srtgroep_omschrijving, 1,2);
|
|
|
|
EXCEPTION WHEN NO_DATA_FOUND
|
|
THEN
|
|
v_ins_srtgroep_omschrijving := SUBSTR(v_ins_srtdeel_code, 1, 2) || '-Onbekend';
|
|
END;
|
|
END;
|
|
|
|
BEGIN
|
|
v_errormsg := 'Bepaal object id - Kijk of het externnr bestaat';
|
|
SELECT d.ins_deel_omschrijving
|
|
INTO v_ins_deel_omschrijving
|
|
FROM ins_v_deel_gegevens dg, ins_deel d
|
|
WHERE dg.ins_deel_key = d.ins_deel_key
|
|
AND dg.alg_gebouw_upper = v_alg_gebouw_code
|
|
AND d.ins_deel_externnr = v_ins_deel_externnr;
|
|
|
|
EXCEPTION WHEN NO_DATA_FOUND
|
|
THEN
|
|
v_ins_deel_omschrijving := NULL;
|
|
END;
|
|
|
|
IF v_ins_deel_omschrijving IS NULL
|
|
THEN
|
|
v_errormsg := 'Bepaal object id - maak een nieuw nummer aan';
|
|
SELECT MAX(FAC.safe_to_number(SUBSTR(ins_deel_omschrijving, INSTR(ins_deel_omschrijving, '-', 1, 3)+1, 100)))
|
|
INTO v_ins_deel_volgnr
|
|
FROM ins_v_deel_gegevens
|
|
WHERE ins_discipline_omschrijving = 'MJOB'
|
|
AND ins_deel_omschrijving LIKE v_ins_srtdeel_code || '%';
|
|
|
|
IF v_ins_deel_volgnr IS NULL
|
|
THEN
|
|
v_ins_deel_volgnr := 0;
|
|
END IF;
|
|
|
|
v_ins_deel_omschrijving := v_ins_srtdeel_code || LPAD(v_ins_deel_volgnr + 1, 3, '0');
|
|
END IF;
|
|
|
|
v_errormsg := 'Objectopmerking ongeldig';
|
|
v_ins_deel_opmerking := TRIM (v_ins_deel_opmerking);
|
|
|
|
IF LENGTH (v_ins_deel_opmerking) > 320
|
|
THEN
|
|
v_ins_deel_opmerking := SUBSTR (v_ins_deel_opmerking, 1, 320);
|
|
fac.imp_writelog (
|
|
p_import_key,
|
|
'W',
|
|
v_aanduiding || v_errormsg,
|
|
'Objectopmerking wordt afgebroken tot ['
|
|
|| v_ins_deel_opmerking
|
|
|| ']'
|
|
);
|
|
END IF;
|
|
|
|
--
|
|
v_errormsg := 'Aantal ongeldig; maximale grootte 999999.99';
|
|
v_ins_deel_aantal := TRIM (v_ins_deel_aantal);
|
|
v_ins_deel_aantal := REPLACE (v_ins_deel_aantal, ',', '.');
|
|
v_ins_deel_aantal_n := NULL;
|
|
|
|
IF (v_ins_deel_aantal IS NOT NULL AND fac.getSetting('ins_explode_objects') = 0)
|
|
THEN
|
|
IF (fac.safe_to_number (v_ins_deel_aantal) IS NULL)
|
|
THEN
|
|
v_ongeldig := 1;
|
|
fac.imp_writelog (p_import_key,
|
|
'W',
|
|
v_aanduiding || v_errormsg,
|
|
'Regel wordt overgeslagen!');
|
|
ELSE
|
|
v_ins_deel_aantal_n := fac.safe_to_number (v_ins_deel_aantal);
|
|
END IF;
|
|
ELSE
|
|
v_ins_deel_aantal_n := 1;
|
|
END IF;
|
|
|
|
--
|
|
v_errorhint := 'Bepaling registratiedatum';
|
|
v_ins_kenmerkwaarde8 := TRIM(v_ins_kenmerkwaarde8);
|
|
IF v_ins_kenmerkwaarde8 IS NOT NULL AND LENGTH(v_ins_kenmerkwaarde8) = 4
|
|
THEN
|
|
v_ins_deel_aanmaak := '01-01-' || TRIM(v_ins_kenmerkwaarde8);
|
|
v_ins_deel_aanmaak_d := TO_DATE(v_ins_deel_aanmaak, 'dd-mm-yyyy');
|
|
END IF;
|
|
|
|
-- De rest alleen ff trimmen.
|
|
v_ins_kenmerkwaarde1 := TRIM (v_ins_kenmerkwaarde1);
|
|
v_ins_kenmerkwaarde2 := TRIM (v_ins_kenmerkwaarde2);
|
|
v_ins_kenmerkwaarde3 := TRIM (v_ins_kenmerkwaarde3);
|
|
v_ins_kenmerkwaarde4 := TRIM (v_ins_kenmerkwaarde4);
|
|
v_ins_kenmerkwaarde5 := TRIM (v_ins_kenmerkwaarde5);
|
|
v_ins_kenmerkwaarde6 := TRIM (v_ins_kenmerkwaarde6);
|
|
v_ins_kenmerkwaarde7 := TRIM (v_ins_kenmerkwaarde7);
|
|
v_ins_kenmerkwaarde8 := TRIM (v_ins_kenmerkwaarde8);
|
|
v_ins_kenmerkwaarde9 := TRIM (v_ins_kenmerkwaarde9);
|
|
v_ins_kenmerkwaarde10 := TRIM (v_ins_kenmerkwaarde10);
|
|
v_ins_kenmerkwaarde11 := TRIM (v_ins_kenmerkwaarde11);
|
|
v_ins_kenmerkwaarde12 := TRIM (v_ins_kenmerkwaarde12);
|
|
v_ins_kenmerkwaarde13 := TRIM (v_ins_kenmerkwaarde13);
|
|
v_ins_kenmerkwaarde14 := TRIM (v_ins_kenmerkwaarde14);
|
|
v_ins_kenmerkwaarde15 := TRIM (v_ins_kenmerkwaarde15);
|
|
v_ins_kenmerkwaarde16 := TRIM (v_ins_kenmerkwaarde16);
|
|
v_ins_kenmerkwaarde17 := TRIM (v_ins_kenmerkwaarde17);
|
|
v_ins_kenmerkwaarde18 := TRIM (v_ins_kenmerkwaarde18);
|
|
v_ins_kenmerkwaarde19 := TRIM (v_ins_kenmerkwaarde19);
|
|
v_ins_kenmerkwaarde20 := TRIM (v_ins_kenmerkwaarde20);
|
|
|
|
-- Insert geformatteerde import record
|
|
IF v_ongeldig = 0
|
|
THEN
|
|
BEGIN
|
|
v_errormsg := 'Fout bij wegschrijven importregel';
|
|
|
|
-- Als uit kenmerkheader een geldige kenmerksoort-key volgt,
|
|
-- dan is kenmerkwaarde<n> gevuld met <key>=<waarde>; zoniet,
|
|
-- dan is kenmerkwaarde<n> gevuld met <waarde>!
|
|
-- NB. Een NULL-waarde resulteert NIET in het wissen van een
|
|
-- kenmerkveld (bijwerken kan wel, maar wissen dus niet)!
|
|
INSERT INTO fac_imp_ins (
|
|
ins_discipline_omschrijving,
|
|
ins_discipline_kostensoort,
|
|
ins_srtgroep_omschrijving,
|
|
ins_srtdeel_code,
|
|
ins_srtdeel_omschrijving,
|
|
ins_deel_omschrijving,
|
|
ins_deel_opmerking,
|
|
alg_locatie_code,
|
|
alg_gebouw_code,
|
|
alg_verdieping_volgnr,
|
|
alg_ruimte_nr,
|
|
ins_kenmerkwaarde1,
|
|
ins_kenmerkwaarde2,
|
|
ins_kenmerkwaarde3,
|
|
ins_kenmerkwaarde4,
|
|
ins_kenmerkwaarde5,
|
|
ins_kenmerkwaarde6,
|
|
ins_kenmerkwaarde7,
|
|
ins_kenmerkwaarde8,
|
|
ins_kenmerkwaarde9,
|
|
ins_kenmerkwaarde10,
|
|
ins_kenmerkwaarde11,
|
|
ins_kenmerkwaarde12,
|
|
ins_kenmerkwaarde13,
|
|
ins_kenmerkwaarde14,
|
|
ins_kenmerkwaarde15,
|
|
ins_kenmerkwaarde16,
|
|
ins_kenmerkwaarde17,
|
|
ins_kenmerkwaarde18,
|
|
ins_kenmerkwaarde19,
|
|
ins_kenmerkwaarde20,
|
|
ins_deel_aanmaak,
|
|
ins_deel_aantal,
|
|
ins_deel_externnr
|
|
)
|
|
VALUES (
|
|
v_ins_discipline_omschrijving,
|
|
v_ins_discipline_kostensoort,
|
|
v_ins_srtgroep_omschrijving,
|
|
v_ins_srtdeel_code,
|
|
v_ins_srtdeel_omschrijving,
|
|
v_ins_deel_omschrijving,
|
|
v_ins_deel_opmerking,
|
|
v_alg_locatie_code,
|
|
v_alg_gebouw_code,
|
|
v_alg_verdieping_volgnr,
|
|
v_alg_ruimte_nr,
|
|
DECODE (v_ins_kenmerk_key1, NULL, v_ins_kenmerkwaarde1, DECODE(v_ins_kenmerk_key1, NULL, NULL, TO_CHAR (v_ins_kenmerk_key1) || '=' || SUBSTR (v_ins_kenmerkwaarde1, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key2, NULL, v_ins_kenmerkwaarde2, DECODE(v_ins_kenmerk_key2, NULL, NULL, TO_CHAR (v_ins_kenmerk_key2) || '=' || SUBSTR (v_ins_kenmerkwaarde2, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key3, NULL, v_ins_kenmerkwaarde3, DECODE(v_ins_kenmerk_key3, NULL, NULL, TO_CHAR (v_ins_kenmerk_key3) || '=' || SUBSTR (v_ins_kenmerkwaarde3, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key4, NULL, v_ins_kenmerkwaarde4, DECODE(v_ins_kenmerk_key4, NULL, NULL, TO_CHAR (v_ins_kenmerk_key4) || '=' || SUBSTR (v_ins_kenmerkwaarde4, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key5, NULL, v_ins_kenmerkwaarde5, DECODE(v_ins_kenmerk_key5, NULL, NULL, TO_CHAR (v_ins_kenmerk_key5) || '=' || SUBSTR (v_ins_kenmerkwaarde5, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key6, NULL, v_ins_kenmerkwaarde6, DECODE(v_ins_kenmerk_key6, NULL, NULL, TO_CHAR (v_ins_kenmerk_key6) || '=' || SUBSTR (v_ins_kenmerkwaarde6, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key7, NULL, v_ins_kenmerkwaarde7, DECODE(v_ins_kenmerk_key7, NULL, NULL, TO_CHAR (v_ins_kenmerk_key7) || '=' || SUBSTR (v_ins_kenmerkwaarde7, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key8, NULL, v_ins_kenmerkwaarde8, DECODE(v_ins_kenmerk_key8, NULL, NULL, TO_CHAR (v_ins_kenmerk_key8) || '=' || SUBSTR (v_ins_kenmerkwaarde8, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key9, NULL, v_ins_kenmerkwaarde9, DECODE(v_ins_kenmerk_key9, NULL, NULL, TO_CHAR (v_ins_kenmerk_key9) || '=' || SUBSTR (v_ins_kenmerkwaarde9, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key10, NULL, v_ins_kenmerkwaarde10, DECODE(v_ins_kenmerk_key10, NULL, NULL, TO_CHAR (v_ins_kenmerk_key10) || '=' || SUBSTR (v_ins_kenmerkwaarde10, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key11, NULL, v_ins_kenmerkwaarde11, DECODE(v_ins_kenmerk_key11, NULL, NULL, TO_CHAR (v_ins_kenmerk_key11) || '=' || SUBSTR (v_ins_kenmerkwaarde11, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key12, NULL, v_ins_kenmerkwaarde12, DECODE(v_ins_kenmerk_key12, NULL, NULL, TO_CHAR (v_ins_kenmerk_key12) || '=' || SUBSTR (v_ins_kenmerkwaarde12, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key13, NULL, v_ins_kenmerkwaarde13, DECODE(v_ins_kenmerk_key13, NULL, NULL, TO_CHAR (v_ins_kenmerk_key13) || '=' || SUBSTR (v_ins_kenmerkwaarde13, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key14, NULL, v_ins_kenmerkwaarde14, DECODE(v_ins_kenmerk_key14, NULL, NULL, TO_CHAR (v_ins_kenmerk_key14) || '=' || SUBSTR (v_ins_kenmerkwaarde14, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key15, NULL, v_ins_kenmerkwaarde15, DECODE(v_ins_kenmerk_key15, NULL, NULL, TO_CHAR (v_ins_kenmerk_key15) || '=' || SUBSTR (v_ins_kenmerkwaarde15, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key16, NULL, v_ins_kenmerkwaarde16, DECODE(v_ins_kenmerk_key16, NULL, NULL, TO_CHAR (v_ins_kenmerk_key16) || '=' || SUBSTR (v_ins_kenmerkwaarde16, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key17, NULL, v_ins_kenmerkwaarde17, DECODE(v_ins_kenmerk_key17, NULL, NULL, TO_CHAR (v_ins_kenmerk_key17) || '=' || SUBSTR (v_ins_kenmerkwaarde17, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key18, NULL, v_ins_kenmerkwaarde18, DECODE(v_ins_kenmerk_key18, NULL, NULL, TO_CHAR (v_ins_kenmerk_key18) || '=' || SUBSTR (v_ins_kenmerkwaarde18, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key19, NULL, v_ins_kenmerkwaarde19, DECODE(v_ins_kenmerk_key19, NULL, NULL, TO_CHAR (v_ins_kenmerk_key19) || '=' || SUBSTR (v_ins_kenmerkwaarde19, 1, 3900))),
|
|
DECODE (v_ins_kenmerk_key20, NULL, v_ins_kenmerkwaarde20, DECODE(v_ins_kenmerk_key20, NULL, NULL, TO_CHAR (v_ins_kenmerk_key20) || '=' || SUBSTR (v_ins_kenmerkwaarde20, 1, 3900))),
|
|
v_ins_deel_aanmaak_d,
|
|
v_ins_deel_aantal_n,
|
|
v_ins_deel_externnr
|
|
);
|
|
|
|
COMMIT;
|
|
v_count_import := v_count_import + 1;
|
|
END;
|
|
|
|
END IF;
|
|
END IF;
|
|
EXCEPTION
|
|
WHEN OTHERS
|
|
THEN
|
|
oracle_err_num := SQLCODE;
|
|
oracle_err_mes := SUBSTR (SQLERRM, 1, 200);
|
|
v_errormsg :=
|
|
v_errormsg
|
|
|| ' ORACLE (error '
|
|
|| oracle_err_num
|
|
|| '/'
|
|
|| oracle_err_mes
|
|
|| ')';
|
|
fac.imp_writelog (p_import_key,
|
|
'W',
|
|
v_aanduiding || v_errormsg,
|
|
'');
|
|
COMMIT;
|
|
END;
|
|
END LOOP;
|
|
|
|
-- We gaan nu de nummering van de objecten aanpassen. Ze hebben allemaal het hoogste bestaande nummer + 1 meegekregen.
|
|
v_alg_gebouw_code := 'Leeg';
|
|
v_ins_srtdeel_code := 'Leeg';
|
|
|
|
FOR rec IN c
|
|
LOOP
|
|
BEGIN
|
|
IF rec.alg_gebouw_code <> v_alg_gebouw_code
|
|
OR rec.ins_srtdeel_code <> v_ins_srtdeel_code
|
|
THEN
|
|
v_ins_deel_volgnr :=
|
|
FAC.safe_to_number (
|
|
SUBSTR (rec.ins_deel_omschrijving, INSTR (rec.ins_deel_omschrijving, '-', 1) + 1, 100));
|
|
v_alg_gebouw_code := rec.alg_gebouw_code;
|
|
v_ins_srtdeel_code := rec.ins_srtdeel_code;
|
|
ELSE
|
|
v_ins_deel_volgnr := v_ins_deel_volgnr + 1;
|
|
|
|
UPDATE fac_imp_ins
|
|
SET ins_deel_omschrijving =
|
|
rec.ins_srtdeel_code
|
|
|| LPAD (v_ins_deel_volgnr, 3, '0')
|
|
WHERE ins_deel_externnr = rec.ins_deel_externnr
|
|
AND alg_gebouw_code = v_alg_gebouw_code;
|
|
END IF;
|
|
END;
|
|
END LOOP;
|
|
|
|
IF (header_is_valid = 1)
|
|
THEN
|
|
fac.imp_writelog (
|
|
p_import_key,
|
|
'S',
|
|
'Objecten/aantal ingelezen importregels: ' || TO_CHAR (v_count_tot),
|
|
''
|
|
);
|
|
fac.imp_writelog (
|
|
p_import_key,
|
|
'S',
|
|
'Objecten/aantal ongeldige niet ingelezen importregels: '
|
|
|| TO_CHAR (v_count_tot - v_count_import),
|
|
''
|
|
);
|
|
END IF;
|
|
|
|
COMMIT;
|
|
EXCEPTION
|
|
WHEN OTHERS
|
|
THEN
|
|
oracle_err_num := SQLCODE;
|
|
oracle_err_mes := SUBSTR (SQLERRM, 1, 200);
|
|
v_errormsg :=
|
|
v_errormsg
|
|
|| ' ORACLE (error '
|
|
|| oracle_err_num
|
|
|| '/'
|
|
|| oracle_err_mes
|
|
|| ')';
|
|
fac.imp_writelog (p_import_key,
|
|
'E',
|
|
v_aanduiding || v_errormsg,
|
|
'Inleesproces objecten afgebroken! regel:' || v_file_index);
|
|
END szdb_import_mjobelementen;
|
|
/
|
|
|
|
|
|
CREATE OR REPLACE PROCEDURE szdb_update_mjobelementen (
|
|
p_import_key IN NUMBER)
|
|
IS
|
|
|
|
BEGIN
|
|
fac_update_ins (p_import_key);
|
|
END;
|
|
/
|
|
|
|
CREATE OR REPLACE PROCEDURE szdb_import_mjobgebreken (p_import_key IN NUMBER)
|
|
IS
|
|
c_delim VARCHAR2 (2) := fac.import_delimiter(p_import_key);
|
|
v_newline fac_imp_file.fac_imp_file_line%TYPE; -- Input line
|
|
v_errormsg VARCHAR2 (1000);
|
|
v_errorhint VARCHAR2 (1000);
|
|
v_file_index NUMBER;
|
|
v_count NUMBER;
|
|
oracle_err_num NUMBER;
|
|
oracle_err_mes VARCHAR2 (200);
|
|
header_is_valid NUMBER;
|
|
v_count_tot NUMBER (10);
|
|
v_count_import NUMBER (10);
|
|
v_ongeldig NUMBER (1);
|
|
v_aanduiding VARCHAR2 (400);
|
|
|
|
v_stdmelding_key NUMBER;
|
|
v_gebrek_code VARCHAR2(100);
|
|
|
|
|
|
-- Overige velden:
|
|
CURSOR c1
|
|
IS
|
|
SELECT *
|
|
FROM fac_imp_file
|
|
WHERE fac_import_key = p_import_key
|
|
ORDER BY fac_imp_file_index;
|
|
|
|
BEGIN
|
|
|
|
FOR rec1 IN c1
|
|
LOOP
|
|
BEGIN
|
|
v_newline := rec1.fac_imp_file_line;
|
|
v_file_index := rec1.fac_imp_file_index;
|
|
v_errormsg := 'Fout bij opvragen importregel';
|
|
v_aanduiding := '';
|
|
v_ongeldig := 0;
|
|
-- Lees alle veldwaarden
|
|
fac.imp_getfield_nr (v_newline, c_delim, 6, v_gebrek_code);
|
|
|
|
IF v_gebrek_code IS NOT NULL AND v_file_index <> 1
|
|
THEN
|
|
BEGIN
|
|
SELECT mld_stdmelding_key
|
|
INTO v_stdmelding_key
|
|
FROM mld_stdmelding
|
|
WHERE mld_stdmelding_code = v_gebrek_code;
|
|
|
|
EXCEPTION WHEN NO_DATA_FOUND
|
|
THEN
|
|
INSERT INTO mld_stdmelding (mld_stdmelding_code,
|
|
mld_ins_discipline_key,
|
|
mld_stdmelding_omschrijving,
|
|
mld_stdmelding_hint,
|
|
mld_stdmelding_subject,
|
|
mld_stdmelding_t_accepttijd,
|
|
mld_stdmelding_t_uitvoertijd,
|
|
mld_stdmelding_t_uitvtijd_pr1,
|
|
mld_stdmelding_t_uitvtijd_pr2,
|
|
mld_stdmelding_t_uitvtijd_pr4,
|
|
alg_onrgoed_niveau,
|
|
alg_onrgoed_obj_niveau,
|
|
ins_srtinst_verplichtstatus,
|
|
mld_stdmelding_slabewaken)
|
|
|
|
SELECT v_gebrek_code,
|
|
d.ins_discipline_key,
|
|
v_gebrek_code || 'Onbekend',
|
|
v_gebrek_code || 'Onbekend',
|
|
0,
|
|
MLD_T_UITVOERTIJD (NULL, 'U'),
|
|
MLD_T_UITVOERTIJD (2, 'D'),
|
|
MLD_T_UITVOERTIJD (NULL, 'D'),
|
|
MLD_T_UITVOERTIJD (NULL, 'D'),
|
|
MLD_T_UITVOERTIJD (NULL, 'D'),
|
|
'G',
|
|
'G',
|
|
2,
|
|
0
|
|
FROM ins_tab_discipline d, ins_srtdiscipline sd
|
|
WHERE REGEXP_SUBSTR (v_gebrek_code, '[[:alpha:]]*[[:digit:]]*') =
|
|
SUBSTR (ins_discipline_omschrijving, 1, INSTR (ins_discipline_omschrijving, ' ') - 1)
|
|
AND d.ins_srtdiscipline_key = sd.ins_srtdiscipline_key
|
|
AND sd.ins_srtdiscipline_omschrijving = 'NEN2767 - Conditiemeting'
|
|
AND ins_discipline_code <> 'GEEN';
|
|
|
|
fac.imp_writelog (p_import_key,
|
|
'I',
|
|
v_gebrek_code || ' aangemaakt.',
|
|
'');
|
|
-- dbms_output.put_line ('Ontbrekende code: ' || v_gebrek_code);
|
|
END;
|
|
END IF;
|
|
END;
|
|
END LOOP;
|
|
|
|
-- Nu de gebreken importeren
|
|
cnd_import_nen2767_results (p_import_key);
|
|
|
|
-- En het externe nummer vervangen door het interne nummer
|
|
UPDATE cnd_imp_nen2767_results r
|
|
SET ins_deel_omschrijving = (SELECT ins_deel_omschrijving
|
|
FROM ins_deel d
|
|
WHERE d.ins_deel_externnr = r.ins_deel_omschrijving)
|
|
WHERE fac_import_key = p_import_key;
|
|
|
|
COMMIT;
|
|
EXCEPTION
|
|
WHEN OTHERS
|
|
THEN
|
|
oracle_err_num := SQLCODE;
|
|
oracle_err_mes := SUBSTR (SQLERRM, 1, 200);
|
|
v_errormsg :=
|
|
v_errormsg
|
|
|| ' ORACLE (error '
|
|
|| oracle_err_num
|
|
|| '/'
|
|
|| oracle_err_mes
|
|
|| ')';
|
|
fac.imp_writelog (p_import_key,
|
|
'E',
|
|
v_aanduiding || v_errormsg,
|
|
'Inleesproces gebreken afgebroken! regel:' || v_file_index);
|
|
END szdb_import_mjobgebreken;
|
|
/
|
|
|
|
|
|
CREATE OR REPLACE PROCEDURE szdb_update_mjobgebreken (
|
|
p_import_key IN NUMBER)
|
|
IS
|
|
BEGIN
|
|
cnd_update_nen2767_results (p_import_key);
|
|
END;
|
|
/
|
|
|
|
-- rapportage om foto's toe te voegen
|
|
CREATE OR REPLACE VIEW szdb_v_upload_foto_script
|
|
AS
|
|
SELECT alg_gebouw_code,
|
|
'cscript "..\..\Fotos\UploadFotoBijGebrek.js" "https://szdb.facilitor.nl/api2" 4201 '
|
|
|| mld_melding_key
|
|
|| ' "'
|
|
|| foto
|
|
|| '"' url
|
|
FROM (SELECT aogg.alg_gebouw_code,
|
|
m.mld_melding_key,
|
|
1 volgorde,
|
|
szdb.imp_getfield_nr (mld_kenmerkmelding_waarde, ':', 1) foto
|
|
FROM mld_kenmerkmelding km, mld_melding m, alg_v_onroerendgoed_gegevens aogg
|
|
WHERE aogg.alg_onroerendgoed_keys = m.mld_alg_onroerendgoed_keys
|
|
AND m.mld_melding_key = km.mld_melding_key
|
|
AND mld_kenmerk_key = 4202
|
|
UNION ALL
|
|
SELECT aogg.alg_gebouw_code,
|
|
m.mld_melding_key,
|
|
2,
|
|
szdb.imp_getfield_nr (mld_kenmerkmelding_waarde, ':', 2)
|
|
FROM mld_kenmerkmelding km, mld_melding m, alg_v_onroerendgoed_gegevens aogg
|
|
WHERE aogg.alg_onroerendgoed_keys = m.mld_alg_onroerendgoed_keys
|
|
AND m.mld_melding_key = km.mld_melding_key
|
|
AND mld_kenmerk_key = 4202
|
|
UNION ALL
|
|
SELECT aogg.alg_gebouw_code,
|
|
m.mld_melding_key,
|
|
3,
|
|
szdb.imp_getfield_nr (mld_kenmerkmelding_waarde, ':', 3)
|
|
FROM mld_kenmerkmelding km, mld_melding m, alg_v_onroerendgoed_gegevens aogg
|
|
WHERE aogg.alg_onroerendgoed_keys = m.mld_alg_onroerendgoed_keys
|
|
AND m.mld_melding_key = km.mld_melding_key
|
|
AND mld_kenmerk_key = 4202
|
|
UNION ALL
|
|
SELECT aogg.alg_gebouw_code,
|
|
m.mld_melding_key,
|
|
4,
|
|
szdb.imp_getfield_nr (mld_kenmerkmelding_waarde, ':', 4)
|
|
FROM mld_kenmerkmelding km, mld_melding m, alg_v_onroerendgoed_gegevens aogg
|
|
WHERE aogg.alg_onroerendgoed_keys = m.mld_alg_onroerendgoed_keys
|
|
AND m.mld_melding_key = km.mld_melding_key
|
|
AND mld_kenmerk_key = 4202)
|
|
WHERE foto IS NOT NULL;
|
|
|
|
------ payload end ------
|
|
|
|
SET DEFINE OFF
|
|
BEGIN adm.systrackscriptId ('$Id$', 0); END;
|
|
/
|
|
|
|
COMMIT;
|
|
SET ECHO OFF
|
|
SPOOL OFF
|
|
SET DEFINE ON
|
|
PROMPT Logfile of this upgrade is: &fcltlogfile
|