Files
Database/FCLT.SRC
Peter Feij 6dd1d06946 2014
svn path=/Database/trunk/; revision=20680
2014-02-18 12:37:20 +00:00

155 lines
4.7 KiB
Plaintext

-- [CREA*.SQL]
--
-- Script tbv het aanmaken van de FACILITOR omgeving in Oracle
-- Copyright 1996-2014 SG|facilitor bv.
-- All rights reserved!
/*
* $Revision$
* $Id$
*/
#include "modules.h"
#include "comsql.h"
SET TIME ON
SET HEADING OFF
SET FEEDBACK OFF
SET ECHO OFF
column fcltlogfile new_value fcltlogfile NOPRINT;
select 'FACILITOR'|| _DBV_STRING || '_' || UPPER(USER || '_' || sys_context('USERENV', 'SERVICE_NAME') || '_' || sys_context('USERENV', 'SERVER_HOST')) || '_' || to_char(sysdate,'YYYYMMDD_HH24MISS') || '.lst' as fcltlogfile from dual;
spool &fcltlogfile
WHENEVER SQLERROR EXIT;
DECLARE
tekst VARCHAR2 (1000);
BEGIN
CASE ASCII('€')
WHEN 191 THEN tekst :='WE8ISO8859P1';
WHEN 128 THEN tekst :='WE8MSWIN1252'; -- De enige goede
ELSE tekst :='UNKNOWN ';
END CASE;
IF tekst <> 'WE8MSWIN1252' THEN
tekst := '=================================================================' || CHR(10)
|| 'Foute clientside NLS_LANG ['|| TO_CHAR(ASCII('€')) ||'] voor deze Facilitor upgrade.' || CHR(10)
|| 'WE8MSWIN1252 is nodig, ik vermoed '|| tekst || CHR(10)
|| 'Geef bijvoorbeeld in Windows voordat SQL*Plus opstart:' || CHR(10)
|| 'SET NLS_LANG=.WE8MSWIN1252' || CHR(10)
|| 'Het upgrade script wordt nu afgebroken!' || CHR(10)
|| '=================================================================' || CHR(10);
RAISE_APPLICATION_ERROR(-20000, 'OR'||'A-' || CHR(10) || tekst);
END IF;
END;
/
WHENEVER SQLERROR CONTINUE;
PROMPT [&fcltlogfile]
PROMPT
PROMPT Copyright 1996-2014 SG|facilitor bv. ALL RIGHTS RESERVED.
PROMPT
PROMPT Dit is de gegenereerde list-file van FCLTnnn.sql welke
PROMPT is gebruikt om de FACILITOR(r) _VERSION omgeving in Oracle aan te
PROMPT maken.
PROMPT
SET LINESIZE 1000
SET DEFINE OFF
SET ECHO ON
#include "adm\adm_tab.src"
#include "adm\adm_pac.src"
/* TABLES */
#include "fac\fac_tab.src"
#include "alg\alg_tab.src"
#include "ins\ins_tab.src"
#include "prs\prs_tab.src"
#include "mld\mld_tab.src"
#include "mrk\mrk_tab.src"
#include "cad\cad_tab.src"
#include "res\res_tab.src"
#include "bez\bez_tab.src"
#include "web\web_tab.src"
#include "cnt\cnt_tab.src"
#include "bes\bes_tab.src"
#include "fin\fin_tab.src"
#include "prj\prj_tab.src"
#include "msg\msg_tab.src"
/* SEQUENCES */
#include "fac\fac_seq.src"
#include "alg\alg_seq.src"
#include "ins\ins_seq.src"
#include "prs\prs_seq.src"
#include "mld\mld_seq.src"
#include "mrk\mrk_seq.src"
#include "cad\cad_seq.src"
#include "res\res_seq.src"
#include "bez\bez_seq.src"
#include "web\web_seq.src"
#include "cnt\cnt_seq.src"
#include "bes\bes_seq.src"
#include "fin\fin_seq.src"
#include "prj\prj_seq.src"
#include "msg\msg_seq.src"
/* INDICES */
#include "fac\fac_ind.src"
#include "alg\alg_ind.src"
#include "ins\ins_ind.src"
#include "prs\prs_ind.src"
#include "mld\mld_ind.src"
#include "mrk\mrk_ind.src"
#include "cad\cad_ind.src"
#include "res\res_ind.src"
#include "bez\bez_ind.src"
#include "web\web_ind.src"
#include "cnt\cnt_ind.src"
#include "bes\bes_ind.src"
#include "fin\fin_ind.src"
#include "prj\prj_ind.src"
#include "msg\msg_ind.src"
/* VIEWS, PACKAGES, TRIGGERS and LOCALES */
#include "_up/recreate.inc"
/* INITIALISATIES */
#include "fac\fac_ini.src"
#include "alg\alg_ini.src"
#include "ins\ins_ini.src"
#include "prs\prs_ini.src"
#include "mld\mld_ini.src"
#include "mrk\mrk_ini.src"
#include "cad\cad_ini.src"
#include "res\res_ini.src"
#include "bez\bez_ini.src"
#include "web\web_ini.src"
#include "cnt\cnt_ini.src"
#include "bes\bes_ini.src"
#include "fin\fin_ini.src"
#include "prj\prj_ini.src"
#include "msg\msg_ini.src"
COMMIT;
///////////////////////////// finally compile all views, triggers etc acc to the latest state ///////
BEGIN DBMS_UTILITY.COMPILE_SCHEMA(USER, FALSE); END;
/
BEGIN fac.registerversion(_VERSIONMAJ, _VERSIONMIN, _VERSIONPATCH, _DBV_STRING, 'NL'); END;
/
REGISTERONCE('$Id$')
COMMIT;
///////////////////////////// Report invalid objects, if any ///////
SET ECHO OFF
SET LINESIZE 132
PROMPT List of all invalid objects after FACILITOR creation:
SELECT 'OR'||'A-'||'DB'|| _DBV_STRING ||' Warning: ' || object_type || ' ' || object_name || ' is ' || status
FROM user_objects
WHERE object_type IN ('VIEW', 'TRIGGER', 'PACKAGE', 'PROCEDURE', 'FUNCTION', 'PACKAGE BODY')
AND status <> 'VALID'
ORDER BY object_name;
SELECT 'FACILITOR/' || USER || ' is now ' || fac.getdbversion() FROM DUAL;
PROMPT Schema initialisatie is gereed, controleer de LST-files.
PROMPT Neem bij vragen, twijfels of problemen contact op met FACILITOR.
SPOOL OFF