AANS#28185 Ook hoofdletter .DWF mag natuurlijk.
Enkele Regexp aangepast zodat extensie ook echt achteraan moet staan. svn path=/Website/trunk/; revision=19976
This commit is contained in:
@@ -142,7 +142,7 @@ function onOtherDrawing()
|
||||
for (; !fc4.atEnd(); fc4.moveNext())
|
||||
{
|
||||
var vTekening0 = fc4.item().Name;
|
||||
if (vTekening0.match(/.dwf$/ig))
|
||||
if (vTekening0.match(/.dwf$/i))
|
||||
{
|
||||
%> <option <%=nn==0?" SELECTED='1'":""%>><%=Server.HTMLEncode(vTekening0)%></option>
|
||||
<%
|
||||
|
||||
@@ -71,8 +71,8 @@ function contour_list(pautfunction, params)
|
||||
else
|
||||
{
|
||||
var fname = oRs("cad_tekening_filenaam").value;
|
||||
fname = fname.replace(/.dwg/g,'');
|
||||
fname = fname.replace(/.dwf/g,'');
|
||||
fname = fname.replace(/.dwg$/i,'');
|
||||
fname = fname.replace(/.dwf$/i,'');
|
||||
var fullnameActual = S("fg_dwf_path") + fname + ".dwf";
|
||||
var fullnameConcept = S("fg_dwf_path_concept") + fname + ".dwf";
|
||||
var fso = new ActiveXObject("Scripting.FileSystemObject");
|
||||
|
||||
@@ -112,7 +112,7 @@ if (!fso.FileExists(fullnameDWF))
|
||||
for (; !fc4.atEnd(); fc4.moveNext())
|
||||
{
|
||||
vTekening0 = fc4.item().Name;
|
||||
if (vTekening0.match(".dwf")||vTekening0.match(".w2d"))
|
||||
if (vTekening0.match(/.dwf$/i)||vTekening0.match(/.w2d$/))
|
||||
{
|
||||
%> <option <%=vTekening0==dwf?"selected='1'":""%>><%=Server.HTMLEncode(vTekening0)%></option>
|
||||
<%
|
||||
|
||||
@@ -52,8 +52,8 @@ if (verdieping_key > 0 || (gebouw_key > 0 && bttype == "T"))
|
||||
+ " AND ct.alg_verdieping_key IS NULL");
|
||||
oRs = Oracle.Execute(sql);
|
||||
var fname = oRs("cad_tekening_filenaam").value;
|
||||
fname = fname.replace(/.dwg/g,'');
|
||||
fname = fname.replace(/.dwf/g,'');
|
||||
fname = fname.replace(/.dwg$/i,'');
|
||||
fname = fname.replace(/.dwf$/i,'');
|
||||
var fullnameConcept = S("fg_dwf_path_concept") + fname + ".dwf";
|
||||
var fso = new ActiveXObject("Scripting.FileSystemObject");
|
||||
concept = fso.FileExists(fullnameConcept);
|
||||
|
||||
@@ -52,8 +52,8 @@ if (floor_key > 0 || (building_key > 1 && bttype == "T")) // alvast een en ander
|
||||
oRs = Oracle.Execute(sql);
|
||||
var cad_tek_key = oRs("cad_tekening_key").value;
|
||||
var fname = oRs("cad_tekening_filenaam").value;
|
||||
fname = fname.replace(/.dwg/g,'');
|
||||
fname = fname.replace(/.dwf/g,'');
|
||||
fname = fname.replace(/.dwg$/i,'');
|
||||
fname = fname.replace(/.dwf$/i,'');
|
||||
var fullnameActual = S("fg_dwf_path") + fname + ".dwf";
|
||||
var fullnameConcept = S("fg_dwf_path_concept") + fname + ".dwf";
|
||||
var fso = new ActiveXObject("Scripting.FileSystemObject");
|
||||
|
||||
Reference in New Issue